GETTING STARTED MANUAL REVISION 2.0
13
Pressing the Page Down button shows the following Liquid Line Solenoid Status screen:
ACTUAL DISPLAY DESCRIPTION
Outputs
Selecting the ‘Outputs’ menu option shows the first 4 Relay Outputs:
ACTUAL DISPLAY DESCRIPTION
Pressing the Page Down button shows the next 4 Relay Outputs:
ACTUAL DISPLAY DESCRIPTION
Continue pressing the Page Down or Page Up buttons to scroll through all the Output screens.
Inputs
Selecting the ‘Inputs’ menu option shows the first 4 Sensor Inputs:
ACTUAL DISPLAY DESCRIPTION
09:56 Outputs
Relays Status
M-1 COMP Lck Off
M-2 LOAD Lck Off
M-3 UNLOAD Lck Off
M-4 LLS 1 Lck Off
Anlog PG PG
HH:MM Screen Title Left/Right Arrow
RO position & names Current status of RO
Using the Left and Right arrow buttons allows user to view all
data for RO’s displayed (Status, Last On, Last Off, Run Time
Today, Cycles Today, Run Time Yesterday, Cycles Yesterday,
Total Run Hours, and Total Cycles)
Switch to AO’s Page up Page down
09:56 Inputs
Sensor Value
M-1 SUCT PSI 66.0P
M-2 DISC PSI 121.3P
M-3 SPAREM-3 ----
M-4 AMPS 52.3A
PG PG
HH:MM Screen Title Left/Right Arrow
SI position & names Current status of SI
Using Left/Right arrow allows user to view all data for SI’s displayed
(Value, Type, Last On, Last Off, Max Value Today, Min Value Today, Run
Time Today, Average Value Today, Cycles Today, Run Time Yesterday, Max
Value Yesterday, Cycles Yesterday, Min Value Yesterday, Total Run
Hours, Average Value Yesterday, and Total Cycles)
Page up Page down
09:56 Outputs
Relays Status
M-5 LIQ INJ On
M-6 HOT GAS On
M-7 LLS 2 On
M-8 SUBCOOLER On
Anlog PG PG
HH:MM Screen Title Left/Right Arrow
RO position & names Current status of RO
Using the Left and Right arrow buttons allows user to view all
data for RO’s displayed (Status, Last On, Last Off, Run Time
Today, Cycles Today, Run Time Yesterday, Cycles Yesterday,
Total Run Hours, and Total Cycles)
Switch to AO’s Page up Page down
09:55 LLS #1 45/54
IS HOLDING
002:43:42
Suction Info
PRES SST TEMP SSH
14.0P 60F 12F 47.0
PG PG
HH:MM LIQUID LINE SOLENOID LEV/ENT
CURRENT CONTROL STATE
TIME IN CURRENT STATE
SUCTION SAT.SUCT. SUCTION SUCT.SHEAT.
PRESSURE TEMP TEMP TEMP
Page Up Page Down
Vista de pagina 12